DumpsFree provides high-quality dumps PDF & dumps VCE for candidates who are willing to pass exams and get certifications soon. We provide dumps free download before purchasing dumps VCE. 100% pass exam!

[Dec-2023] HP ACA - Network Security HPE6-A84 Exam Practice Dumps [Q17-Q39]

Share

[Dec-2023] HP ACA - Network Security HPE6-A84 Exam Practice Dumps

2023 HPE6-A84 Premium Files Test pdf - Free Dumps Collection


HPE6-A84 certification exam is intended for experienced network security professionals who want to enhance their skills and knowledge in Aruba security solutions. Candidates who pass HPE6-A84 exam will gain a deep understanding of network security concepts and techniques, as well as gain practical experience in implementing and managing Aruba security solutions.

 

NEW QUESTION # 17
Refer to the scenario.
A customer has an Aruba ClearPass cluster. The customer has AOS-CX switches that implement 802.1X authentication to ClearPass Policy Manager (CPPM).
Switches are using local port-access policies.
The customer wants to start tunneling wired clients that pass user authentication only to an Aruba gateway cluster. The gateway cluster should assign these clients to the "eth-internet" role. The gateway should also handle assigning clients to their VLAN, which is VLAN 20.
The plan for the enforcement policy and profiles is shown below:

The gateway cluster has two gateways with these IP addresses:
* Gateway 1
o VLAN 4085 (system IP) = 10.20.4.21
o VLAN 20 (users) = 10.20.20.1
o VLAN 4094 (WAN) = 198.51.100.14
* Gateway 2
o VLAN 4085 (system IP) = 10.20.4.22
o VLAN 20 (users) = 10.20.20.2
o VLAN 4094 (WAN) = 198.51.100.12
* VRRP on VLAN 20 = 10.20.20.254
The customer requires high availability for the tunnels between the switches and the gateway cluster. If one gateway falls, the other gateway should take over its tunnels. Also, the switch should be able to discover the gateway cluster regardless of whether one of the gateways is in the cluster.
What is one change that you should make to the solution?

  • A. Remove VLAN assignments from role configurations on the gateways.
  • B. Configure the UBT solution to use VLAN extend mode.
  • C. Configure edge ports in VLAN trunk mode.
  • D. Change the ubt-client-vlan to VLAN 13.

Answer: A


NEW QUESTION # 18
When would you implement BPDU protection on an AOS-CX switch port versus BPDU filtering?

  • A. Use BPDU protection on edge ports to protect against rogue devices when the switch implements MSTP; use BPDU filtering to protect against rogue devices when the switch implements PVSTP+.
  • B. Use BPDU protection on edge ports to prevent rogue devices from connecting; use BPDU filtering on inter-switch ports for specialized use cases.
  • C. Use BPDU protection on inter-switch ports to ensure that they are selected as root; use BPDU filtering on edge ports to prevent rogue devices from connecting.
  • D. Use BPDU protection on edge ports to permanently lock out rogue devices; use BPDU filtering on edge ports to temporarily lock out rogue devices.

Answer: B

Explanation:
Explanation
BPDU (Bridge Protocol Data Unit) is a message that is exchanged between switches to maintain the spanning tree topology and prevent loops. BPDU protection and BPDU filtering are two features that can be configured on AOS-CX switch ports to enhance security and performance.
BPDU protection is a feature that disables a port if it receives a BPDU, indicating that an unauthorized switch or device has been connected to the port. BPDU protection is typically used on edge ports, which are ports that connect to end devices such as PCs or printers, and are not expected to receive BPDUs. BPDU protection prevents rogue devices from connecting to the network and affecting the spanning tree topology.
BPDU filtering is a feature that prevents a port from sending or receiving BPDUs, effectively isolating the port from the spanning tree topology. BPDU filtering is typically used on inter-switch ports, which are ports that connect to other switches, for specialized use cases such as creating a separate spanning tree domain or reducing the overhead of BPDUs. BPDU filtering should be used with caution, as it can create loops or inconsistencies in the network.
You can find more information about how to configure BPDU protection and BPDU filtering on AOS-CX switch ports in the [Configuring Spanning Tree Protocol - Aruba] page and the [AOS-CX Switching Configuration Guide] page. The other options are not correct because they either use BPDU protection or BPDU filtering on the wrong type of ports or for the wrong purpose. For example, using BPDU protection on inter-switch ports would disable the ports if they receive BPDUs, which are expected in normal operation.
Using BPDU filtering on edge ports would allow rogue devices to connect to the network and create loops or affect the spanning tree topology.


NEW QUESTION # 19
A customer needs you to configure Aruba ClearPass Policy Manager (CPPM) to authenticate domain users on domain computers. Domain users, domain computers, and domain controllers receive certificates from a Windows CA. CPPM should validate these certificates and verify that the users and computers have accounts in Windows AD. The customer requires encryption for all communications between CPPM and the domain controllers.
You have imported the root certificate for the Windows CA to the ClearPass CA Trust list.
Which usages should you add to it based on these requirements?

  • A. Radec and Aruba infrastructure
  • B. EAP and AD/LDAP Server
  • C. EAP and Radsec
  • D. LDAP and Aruba infrastructure

Answer: C


NEW QUESTION # 20
You need to install a certificate on a standalone Aruba Mobility Controller (MC). The MC will need to use the certificate for the Web UI and for implementing RadSec with Aruba ClearPass Policy Manager. You have been given a certificate with these settings:
Subject: CN=mc41.site94.example.com
* No SANs
* Issuer: CN=ca41.example.com
EKUs: Server Authentication, Client Authentication
What issue does this certificate have for the purposes for which the certificate is intended?

  • A. It specifies domain info in the CN field instead of the DC field.
  • B. It is issued by a private CA.
  • C. It has conflicting EKUs.
  • D. It lacks a DNS SAN.

Answer: D

Explanation:
Explanation
A DNS SAN (Subject Alternative Name) is an extension of the X.509 certificate standard that allows specifying additional hostnames or IP addresses that the certificate can be used for. A DNS SAN is useful for validating the identity of the server or client that presents the certificate, especially when the common name (CN) field does not match the hostname or IP address of the server or client.
In this case, the certificate has a CN of mc41.site94.example.com, which is the fully qualified domain name (FQDN) of the standalone Aruba Mobility Controller (MC). However, this CN may not match the hostname or IP address that the MC uses for the Web UI or for implementing RadSec with Aruba ClearPass Policy Manager. For example, if the MC uses a different FQDN, such as mc41.example.com, or an IP address, such as 192.168.1.41, for these purposes, then the certificate would not be valid for them. Therefore, the certificate should have a DNS SAN that includes all the possible hostnames or IP addresses that the MC may use for the Web UI and RadSec.


NEW QUESTION # 21
You are setting up Aruba ClearPass Policy Manager (CPPM) to enforce EAP-TLS authentication with Active Directory as the authentication source. The company wants to prevent users with disabled accounts from connecting even if those users still have valid certificates.
As the first part of meeting these criteria, what should you do to enable CPPM to determine where accounts are enabled in AD or not?

  • A. Add an Endpoint Context Server to the domain controller with actions for querying the domain controller for account status.
  • B. Add a custom attribute for userAccountControl to the filters in the AD authentication source.
  • C. Install a Microsoft Active Directory extension in Aruba ClearPass Guest and set up an HTTP authentication source that points to that extension.
  • D. Enable OCSP in the EAP-TLS authentication method settings and configure an OCSP override to the domain controller FQDN.

Answer: B

Explanation:
Explanation
According to the ClearPass Policy Manager User Guide1, userAccountControl is a custom attribute in Active Directory that contains a set of flags that define the properties and behavior of user accounts. One of these flags is ACCOUNTDISABLE, which indicates whether the account is disabled or not. By adding this attribute to the filters in the AD authentication source, CPPM can retrieve this attribute for each user and use it as a condition in the enforcement policies to prevent users with disabled accounts from connecting even if they have valid certificates. Therefore, option C is the correct answer.


NEW QUESTION # 22
Refer to the scenario.
# Introduction to the customer
You are helping a company add Aruba ClearPass to their network, which uses Aruba network infrastructure devices.
The company currently has a Windows domain and Windows CA. The Window CA issues certificates to domain computers, domain users, and servers such as domain controllers. An example of a certificate issued by the Windows CA is shown here.


The company is in the process of adding Microsoft Endpoint Manager (Intune) to manage its mobile clients.
The customer is maintaining the on-prem AD for now and uses Azure AD Connect to sync with Azure AD.
# Requirements for issuing certificates to mobile clients
The company wants to use ClearPass Onboard to deploy certificates automatically to mobile clients enrolled in Intune. During this process, Onboard should communicate with Azure AD to validate the clients. High availability should also be provided for this scenario; in other words, clients should be able to get certificates from Subscriber 2 if Subscriber 1 is down.
The Intune admins intend to create certificate profiles that include a UPN SAN with the UPN of the user who enrolled the device.
# Requirements for authenticating clients
The customer requires all types of clients to connect and authenticate on the same corporate SSID.
The company wants CPPM to use these authentication methods:
* EAP-TLS to authenticate users on mobile clients registered in Intune
* TEAR, with EAP-TLS as the inner method to authenticate Windows domain computers and the users on them To succeed, EAP-TLS (standalone or as a TEAP method) clients must meet these requirements:
Their certificate is valid and is not revoked, as validated by OCSP
The client's username matches an account in AD
# Requirements for assigning clients to roles
After authentication, the customer wants the CPPM to assign clients to ClearPass roles based on the following rules:
* Clients with certificates issued by Onboard are assigned the "mobile-onboarded" role
* Clients that have passed TEAP Method 1 are assigned the "domain-computer" role Clients in the AD group "Medical" are assigned the "medical-staff" role Clients in the AD group "Reception" are assigned to the "reception-staff" role The customer requires CPPM to assign authenticated clients to AOS firewall roles as follows:
* Assign medical staff on mobile-onboarded clients to the "medical-mobile" firewall role
* Assign other mobile-onboarded clients to the "mobile-other" firewall role
* Assign medical staff on domain computers to the "medical-domain" firewall role
* All reception staff on domain computers to the "reception-domain" firewall role
* All domain computers with no valid user logged in to the "computer-only" firewall role
* Deny other clients access
# Other requirements
Communications between ClearPass servers and on-prem AD domain controllers must be encrypted.
# Network topology
For the network infrastructure, this customer has Aruba APs and Aruba gateways, which are managed by Central. APs use tunneled WLANs, which tunnel traffic to the gateway cluster. The customer also has AOS-CX switches that are not managed by Central at this point.

# ClearPass cluster IP addressing and hostnames
A customer's ClearPass cluster has these IP addresses:
* Publisher = 10.47.47.5
* Subscriber 1 = 10.47.47.6
* Subscriber 2 = 10.47.47.7
* Virtual IP with Subscriber 1 and Subscriber 2 = 10.47.47.8
The customer's DNS server has these entries
* cp.acnsxtest.com = 10.47.47.5
* cps1.acnsxtest.com = 10.47.47.6
* cps2.acnsxtest.com = 10.47.47.7
* radius.acnsxtest.com = 10.47.47.8
* onboard.acnsxtest.com = 10.47.47.8
On CPPM, you are creating the authentication method shown in the exhibit below:

You will use the method for standalone EAP-TLS and for inner methods in TEAP.
What should you do?

  • A. Enable certificate comparison.
  • B. Enable authorization.
  • C. Configure OCSP override and leave the OCSP URL blank.
  • D. Configure OCSP override and set the OCSP URL to localhost/onboard/mdps ocspphp/2

Answer: D


NEW QUESTION # 23
You are working with a developer to design a custom NAE script for a customer. The NAE agent should trigger an alert when ARP inspection drops packets on a VLAN. The customer wants the admins to be able to select the correct VLAN ID for the agent to monitor when they create the agent.
What should you tell the developer to do?

  • A. Define a VLAN ID parameter; reference that parameter when defining the monitor URI.
  • B. Use this variable, %{vlan-id} when defining the monitor URI in the NAE agent script.
  • C. Create multiple monitors within the script from which admins can select when they create the agent.
  • D. Use a callback action to collect the ID of the VLAN on which admins have enabled NAE monitoring.

Answer: A

Explanation:
Explanation
A custom NAE script is a Python script that defines the monitors, the alert-trigger logic, and the remedial actions for an NAE agent. A monitor is a URI that specifies the data source and the data type that the NAE agent should collect and analyze. For example, to monitor the ARP inspection statistics on a VLAN, the monitor URI would be something like this:

where <vlan-id> is the ID of the VLAN to be monitored.
To allow the admins to select the correct VLAN ID for the agent to monitor when they create the agent, you need to define a VLAN ID parameter in the NAE script. A parameter is a variable that can be set by the user when creating or modifying an agent. A parameter can be referenced in other parts of the script by using the syntax ${parameter-name}. For example, to define a VLAN ID parameter and reference it in the monitor URI, you would write something like this:

This way, when the admins create or modify the agent, they can enter the VLAN ID that they want to monitor, and the NAE script will use that value in the monitor URI.
You can find more information about how to write custom NAE scripts and use parameters in the NAE Scripting Guide


NEW QUESTION # 24
Refer to the scenario.
A customer has an Aruba ClearPass cluster. The customer has AOS-CX switches that implement 802.1X authentication to ClearPass Policy Manager (CPPM).
Switches are using local port-access policies.
The customer wants to start tunneling wired clients that pass user authentication only to an Aruba gateway cluster. The gateway cluster should assign these clients to the "eth-internet" role. The gateway should also handle assigning clients to their VLAN, which is VLAN 20.
The plan for the enforcement policy and profiles is shown below:

The gateway cluster has two gateways with these IP addresses:
* Gateway 1
o VLAN 4085 (system IP) = 10.20.4.21
o VLAN 20 (users) = 10.20.20.1
o VLAN 4094 (WAN) = 198.51.100.14
* Gateway 2
o VLAN 4085 (system IP) = 10.20.4.22
o VLAN 20 (users) = 10.20.20.2
o VLAN 4094 (WAN) = 198.51.100.12
* VRRP on VLAN 20 = 10.20.20.254
The customer requires high availability for the tunnels between the switches and the gateway cluster. If one gateway falls, the other gateway should take over its tunnels. Also, the switch should be able to discover the gateway cluster regardless of whether one of the gateways is in the cluster.
What is one change that you should make to the solution?

  • A. Remove VLAN assignments from role configurations on the gateways.
  • B. Configure the UBT solution to use VLAN extend mode.
  • C. Configure edge ports in VLAN trunk mode.
  • D. Change the ubt-client-vlan to VLAN 13.

Answer: A

Explanation:
Explanation
The UBT solution requires that the VLAN assignments for the wired clients are done by the gateway, not by the switch. Therefore, the role configurations on the gateways should not have any VLAN assignments, as they would override the VLAN 20 that is specified in the enforcement profile. Instead, the role configurations should only have policies that define the access rights for the clients in the "eth-internet" role. This way, the gateway can assign the clients to VLAN 20 and apply the appropriate policies based on their role1


NEW QUESTION # 25
Refer to the scenario.
A customer is migrating from on-prem AD to Azure AD as its sole domain solution. The customer also manages both wired and wireless devices with Microsoft Endpoint Manager (Intune).
The customer wants to improve security for the network edge. You are helping the customer design a ClearPass deployment for this purpose. Aruba network devices will authenticate wireless and wired clients to an Aruba ClearPass Policy Manager (CPPM) cluster (which uses version 6.10).
The customer has several requirements for authentication. The clients should only pass EAP-TLS authentication if a query to Azure AD shows that they have accounts in Azure AD. To further refine the clients' privileges, ClearPass also should use information collected by Intune to make access control decisions.
You are planning to use Azure AD as the authentication source in 802.1X services.
What should you make sure that the customer understands is required?

  • A. CPPM's RADIUS certificate was imported as trusted in the Azure AD directory
  • B. Azure AD Domain Services
  • C. Windows 365 subscriptions
  • D. An app registration on Azure AD that references the CPPM's FQDN

Answer: D

Explanation:
Explanation
To use Azure AD as the authentication source in 802.1X services, you need to configure CPPM as a SAML service provider and Azure AD as a SAML identity provider. This allows CPPM to use Azure AD for user authentication and role mapping. To do this, you need to create an app registration on Azure AD that references the CPPM's FQDN as the reply URL and the entity ID. You also need to grant the app registration the required permissions to access user information from Azure AD1


NEW QUESTION # 26
Refer to the scenario.
A customer has an Aruba ClearPass cluster. The customer has AOS-CX switches that implement 802.1X authentication to ClearPass Policy Manager (CPPM).
Switches are using local port-access policies.
The customer wants to start tunneling wired clients that pass user authentication only to an Aruba gateway cluster. The gateway cluster should assign these clients to the "eth-internet" role. The gateway should also handle assigning clients to their VLAN, which is VLAN 20.
The plan for the enforcement policy and profiles is shown below:

The gateway cluster has two gateways with these IP addresses:
* Gateway 1
o VLAN 4085 (system IP) = 10.20.4.21
o VLAN 20 (users) = 10.20.20.1
o VLAN 4094 (WAN) = 198.51.100.14
* Gateway 2
o VLAN 4085 (system IP) = 10.20.4.22
o VLAN 20 (users) = 10.20.20.2
o VLAN 4094 (WAN) = 198.51.100.12
* VRRP on VLAN 20 = 10.20.20.254
The customer requires high availability for the tunnels between the switches and the gateway cluster. If one gateway falls, the other gateway should take over its tunnels. Also, the switch should be able to discover the gateway cluster regardless of whether one of the gateways is in the cluster.
Assume that you have configured the correct UBT zone and port-access role settings. However, the solution is not working.
What else should you make sure to do?

  • A. Create a new VLAN on the AOS-CX switch and configure that VLAN as the UBT client VLAN.
  • B. Change the port-access auth-mode mode to client-mode on any edge ports to which tunneled clients might connect.
  • C. Assign sufficient VIA licenses to the gateways based on the number of wired clients that will connect.
  • D. Assign VLAN 20 as the access VLAN on any edge ports to which tunneled clients might connect.

Answer: A

Explanation:
Explanation
The correct answer is B. Create a new VLAN on the AOS-CX switch and configure that VLAN as the UBT client VLAN.
User-based tunneling (UBT) is a feature that allows the AOS-CX switches to tunnel the traffic from wired clients to a mobility gateway cluster, where they can be assigned a role and a VLAN based on their authentication and authorization 1. To enable UBT, the switches need to have a UBT zone configured with the IP addresses of the gateways, and a UBT client VLAN configured with the ubt-client-vlan command 2.
The UBT client VLAN is a special VLAN that is used to encapsulate the traffic from the tunneled clients before sending it to the gateways. The UBT client VLAN must be different from any other VLANs used on the switch or the network, and it must not be assigned to any ports or interfaces on the switch 2. The UBT client VLAN is only used internally by the switch for UBT, and it is not visible to the clients or the gateways.
In this scenario, the customer wants to tunnel the clients that pass user authentication to the gateway cluster, where they will be assigned to VLAN 20. Therefore, the switch must have a UBT client VLAN configured that is different from VLAN 20 or any other VLANs on the network. For example, the switch can use VLAN
4000 as the UBT client VLAN, as shown in one of the web search results 3. The switch must also have a UBT zone configured with the system IP addresses of the gateways as the primary and backup controllers, as explained in question 3.
The other options are not correct or relevant for this issue:
Option A is not correct because assigning VLAN 20 as the access VLAN on any edge ports to which tunneled clients might connect would conflict with UBT. The access VLAN is the VLAN that is assigned to untagged traffic on a port, and it is used for local switching on the switch 4. If VLAN 20 is assigned as the access VLAN, then the traffic from the clients will not be tunneled to the gateways, but rather switched locally on VLAN 20. This would defeat the purpose of UBT and cause inconsistency in role and VLAN assignment.
Option C is not correct because VIA licenses are not required for UBT. VIA licenses are required for enabling VPN services on Aruba Mobility Controllers for remote access clients using Aruba Virtual Intranet Access (VIA) software . VIA licenses are not related to UBT or wired clients.
Option D is not correct because changing the port-access auth-mode mode to client-mode on any edge ports to which tunneled clients might connect would not affect UBT. The port-access auth-mode mode determines how a port handles authentication requests from multiple clients connected to a single port .
Client-mode is the default mode that allows only one client per port, while multi-client-mode allows multiple clients per port. The port-access auth-mode mode does not affect how UBT works or how traffic is tunneled from a port.


NEW QUESTION # 27
Refer to the scenario.
A customer has an AOS10 architecture that is managed by Aruba Central. Aruba infrastructure devices authenticate clients to an Aruba ClearPass cluster.
In Aruba Central, you are examining network traffic flows on a wireless IoT device that is categorized as
"Raspberry Pi" clients. You see SSH traffic. You then check several more wireless IoT clients and see that they are sending SSH also.
You want a relatively easy way to communicate the information that an IoT client has used SSH to Aruba CPPM.
What is one prerequisite?

  • A. Create an API application and token within the REST API settings.
  • B. Obtain a data collector token from Central's platform integration settings.
  • C. In CPPM's CA trust list, add the Aruba Infrastructure usage to the DigiCert certificate.
  • D. Enable event processing on subscribers in the ClearPass cluster.

Answer: B


NEW QUESTION # 28
Refer to the scenario.
A customer requires these rights for clients in the "medical-mobile" AOS firewall role on Aruba Mobility Controllers (MCs):
Permitted to receive IP addresses with DHCP
Permitted access to DNS services from 10.8.9.7 and no other server
Permitted access to all subnets in the 10.1.0.0/16 range except denied access to 10.1.12.0/22 Denied access to other 10.0.0.0/8 subnets Permitted access to the Internet Denied access to the WLAN for a period of time if they send any SSH traffic Denied access to the WLAN for a period of time if they send any Telnet traffic Denied access to all high-risk websites External devices should not be permitted to initiate sessions with "medical-mobile" clients, only send return traffic.
The exhibits below show the configuration for the role.

There are multiple issues with the configuration.
What is one of the changes that you must make to the policies to meet the scenario requirements? (In the options, rules in a policy are referenced from top to bottom. For example, "medical-mobile" rule 1 is "ipv4 any any svc-dhcp permit," and rule 8 is "ipv4 any any any permit'.)

  • A. In the "medical-mobile" policy, change the subnet mask in rule 3 to 255.255.248.0.
  • B. In the "medical-mobile" policy, move rules 6 and 7 to the top of the list.
  • C. In the "medical-mobile" policy, change the source in rule 1 to "user."
  • D. Move the rule in the "apprf-medical-mobile-sacl" policy between rules 7 and 8 in the "medical-mobile" policy.

Answer: A


NEW QUESTION # 29
A customer requires a secure solution for connecting remote users to the corporate main site. You are designing a client-to-site virtual private network (VPN) based on Aruba VIA and Aruba Mobility Controllers acting as VPN Concentrators (VPNCs). Remote users will first use the VIA client to contact the VPNCs and obtain connection settings.
The users should only be allowed to receive the settings if they are the customer's "RemoteEmployees" AD group. After receiving the settings, the VIA clients will automatically establish VPN connections, authenticating to CPPM with certificates.
What should you do to help ensure that only authorized users obtain VIA connection settings?

  • A. Set up the VPNCs' VIA web authentication profile to use CPPM as the authentication server; set up a service on CPPM that uses AD as the authentication source.
  • B. Set up the VPNCs' VIA web authentication profile to use an AD domain controller as the LDAP server.
  • C. Set up the VPNCs' VIA connection profile to use one authentication profile, which is set to the AD domain controller's hostname.
  • D. Set up the VPNCs' VIA connection profile to use two authentication profiles, one RADIUS profile to CPPM and one LDAP profile to AD.

Answer: A

Explanation:
Explanation
The VIA web authentication profile is used to authenticate the users who want to download the VIA connection settings from the VPNCs. The VPNCs can use either an internal database or an external server (such as RADIUS or LDAP) as the authentication source for this profile. To ensure that only authorized users obtain VIA connection settings, you should use CPPM as the external server and configure a service on CPPM that uses AD as the authentication source. This way, you can leverage the role mapping and enforcement features of CPPM to check if the users belong to the "RemoteEmployees" AD group and grant or deny them access accordingly1 The other options are not correct because they do not allow you to verify the users' AD group membership before providing them with VIA connection settings. Option B would only check the users' credentials against AD, but not their group membership. Option C would only apply to the VPN connection phase, not the VIA connection settings phase. Option D would not work because the VPNCs do not support LDAP as an authentication source for VIA connection profiles2


NEW QUESTION # 30
Refer to the scenario.
An organization wants the AOS-CX switch to trigger an alert if its RADIUS server (cp.acnsxtest.local) rejects an unusual number of client authentication requests per hour. After some discussions with other Aruba admins, you are still not sure how many rejections are usual or unusual. You expect that the value could be different on each switch.
You are helping the developer understand how to develop an NAE script for this use case.
You are helping the developer find the right URI for the monitor.
Refer to the exhibit.

You have used the REST API reference interface to submit a test call. The results are shown in the exhibit.
Which URI should you give to the developer?

  • A. /rest/v1/system/vrfs/mgmt/radius/servers/cp.acnsxtest.local/2083/tcp?attributes=authstatistics?attributes=a
  • B. /rest/v1/system/vrfs/mgmt/radius/servers/cp.acnsxtest.local/2083/tcp?attributes=authstatistics
  • C. /rest/v1/system/vrfs/mgmt/radius/servers/cp.acnsxtest.local/2083/tcp?attributes=authstatistics.access_rejec
  • D. /rest/v1/system/vrfs/mgmt/radius/_servers/cp.acnsxtest.local/2083/tcp

Answer: C

Explanation:
Explanation
This is because this URI specifies the exact attribute that contains the number of access rejects from the RADIUS server, which is the information that the NAE script needs to monitor and trigger an alert.
A: /rest/v1/system/vrfs/mgmt/radius/servers/cp.acnsxtest.local/2083/tcp?attributes=authstatistics. This is not the correct URI because it returns the entire authstatistics object, which contains more information than the access rejects, such as access accepts, challenges, timeouts, etc. This might make the NAE script more complex and inefficient to parse and process the data.
B: /rest/v1/system/vrfs/mgmt/radius/servers/cp.acnsxtest.local/2083/tcp?attributes=authstatistics?attributes=access_ This is not a valid URI because it has two question marks, which is a syntax error. The question mark is used to indicate the start of the query string, which can have one or more parameters separated by ampersands. The correct way to specify multiple attributes is to use a comma-separated list after the question mark, such as?attributes=attr1,attr2,attr3.
C: /rest/v1/system/vrfs/mgmt/radius/_servers/cp.acnsxtest.local/2083/tcp. This is not a valid URI because it has an extra underscore before servers, which is a typo. The correct resource name is servers, not _servers.
Moreover, this URI does not specify any attributes, which means it will return the default attributes of the RADIUS server object, such as name, port, protocol, etc., but not the authstatistics or access_rejects.


NEW QUESTION # 31
Refer to the scenario.
A customer has asked you to review their AOS-CX switches for potential vulnerabilities. The configuration for these switches is shown below:

What is one immediate remediation that you should recommend?

  • A. Either disabling DHCPv4-snoopinq or leaving it enabled, but also enabling ARP inspection
  • B. Disabling Telnet
  • C. Changing the switch's DNS server to the mgmt VRF
  • D. Setting the clock manually instead of using NTP

Answer: B

Explanation:
Explanation
According to the AOS-CX Switches Multiple Vulnerabilities1, one of the vulnerabilities (CVE-2021-41001) affects the Telnet service on AOS-CX switches. This vulnerability allows an unauthenticated remote attacker to cause a denial-of-service condition on the switch by sending specially crafted Telnet packets. The impact of this vulnerability is high, as it could result in a loss of management access and network disruption. Therefore, one immediate remediation that you should recommend is to disable Telnet on the switch. This way, the switch can prevent any malicious Telnet traffic from reaching it and avoid the exploitation of this vulnerability.


NEW QUESTION # 32
You are configuring gateway IDS/IPS settings in Aruba Central.
For which reason would you set the Fail Strategy to Bypass?

  • A. To enable the gateway to honor the allowlist settings configured in IDS/IPS policies
  • B. To permit traffic if the IPS engine falls to inspect It
  • C. To avoid wasting IPS engine resources on filtering traffic for unauthenticated clients
  • D. To tell gateways to stop enforcing IDS/IPS policies if they lose connectivity to the Internet

Answer: B

Explanation:
Explanation
The Fail Strategy is a configuration option for the IPS mode of inspection on Aruba gateways. It defines the action to be taken when the IPS engine crashes and cannot inspect the traffic. There are two possible options for the Fail Strategy: Bypass and Block1 If you set the Fail Strategy to Bypass, you are telling the gateway to allow the traffic to flow without inspection when the IPS engine fails. This option ensures that there is no disruption in the network connectivity, but it also exposes the network to potential threats that are not detected or prevented by the IPS engine1 If you set the Fail Strategy to Block, you are telling the gateway to stop the traffic flow until the IPS engine resumes inspection. This option ensures that there is no compromise in the network security, but it also causes a loss of network connectivity for the duration of the IPS engine failure1


NEW QUESTION # 33
Refer to the scenario.
This customer is enforcing 802.1X on AOS-CX switches to Aruba ClearPass Policy Manager (CPPM). The customer wants switches to download role settings from CPPM. The "reception-domain" role must have these settings:
- Assigns clients to VLAN 14 on switch 1, VLAN 24 on switch 2, and so on.
- Filters client traffic as follows:
- Clients are permitted full access to 10.1.5.0/24 and the Internet
- Clients are denied access to 10.1.0.0/16
The switch topology is shown here:

How should you configure the VLAN setting for the reception role?

  • A. Create a separate enforcement profile with a different VLAN ID for each switch. Add all profiles to the profile list in the appropriate enforcement policy rule.
  • B. Assign a number-based ID to the access layer switches. Then use this variable in the enforcement profile VLAN settings: %(NAS-ID]4.
  • C. Assign a consistent name to VLAN 14, 24, or 34 on each access layer switch and reference that name in the enforcement profile VLAN settings.
  • D. Configure the enforcement profile as a downloadable role, but specify only the role name and leave the VLAN undefined. Then define a 'reception' role with the correct VLAN setting on each individual access layer switch.

Answer: C


NEW QUESTION # 34
A customer has an AOS 10 architecture, which includes Aruba APs. Admins have recently enabled WIDS at the high level. They also enabled alerts and email notifications for several events, as shown in the exhibit.

Admins are complaining that they are getting so many emails that they have to ignore them, so they are going to turn off all notifications.
What is one step you could recommend trying first?

  • A. Disable just the Rogue AP and Client Attack Detected alerts, as they overlap with the Infrastructure Attack Detected alert.
  • B. Send the email notifications directly to a specific folder, and only check the folder once a week.
  • C. Disable email notifications for Roque AP, but leave the Infrastructure Attack Detected and Client Attack Detected notifications on.
  • D. Change the WIDS level to custom, and enable only the checks most likely to indicate real threats.

Answer: D


NEW QUESTION # 35
Refer to the scenario.
An organization wants the AOS-CX switch to trigger an alert if its RADIUS server (cp.acnsxtest.local) rejects an unusual number of client authentication requests per hour. After some discussions with other Aruba admins, you are still not sure how many rejections are usual or unusual. You expect that the value could be different on each switch.
You are helping the developer understand how to develop an NAE script for this use case.
You are helping a customer define an NAE script for AOS-CX switches. The script will monitor statistics from a RADIUS server defined on the switch. You want to future proof the script by enabling admins to select a different hostname or IP address for the monitored RADIUS server when they create an agent from the script.
What should you recommend?

  • A. Use this variable, %{radius-ipV when defining the monitor URI in the NAE agent script.
  • B. Define a parameter for the RADIUS server; reference that parameter instead of the server name/ip when defining the monitor URI.
  • C. Make the script editable so that admins can edit it on demand when they are creating scripts.
  • D. Use a callback action to collect the name of any RADIUS servers defined on the switch at the time the agent is created.

Answer: B


NEW QUESTION # 36
Refer to the scenario.
# Introduction to the customer
You are helping a company add Aruba ClearPass to their network, which uses Aruba network infrastructure devices.
The company currently has a Windows domain and Windows CA. The Window CA issues certificates to domain computers, domain users, and servers such as domain controllers. An example of a certificate issued by the Windows CA is shown here.


The company is in the process of adding Microsoft Endpoint Manager (Intune) to manage its mobile clients.
The customer is maintaining the on-prem AD for now and uses Azure AD Connect to sync with Azure AD.
# Requirements for issuing certificates to mobile clients
The company wants to use ClearPass Onboard to deploy certificates automatically to mobile clients enrolled in Intune. During this process, Onboard should communicate with Azure AD to validate the clients. High availability should also be provided for this scenario; in other words, clients should be able to get certificates from Subscriber 2 if Subscriber 1 is down.
The Intune admins intend to create certificate profiles that include a UPN SAN with the UPN of the user who enrolled the device.
# Requirements for authenticating clients
The customer requires all types of clients to connect and authenticate on the same corporate SSID.
The company wants CPPM to use these authentication methods:
EAP-TLS to authenticate users on mobile clients registered in Intune
TEAR, with EAP-TLS as the inner method to authenticate Windows domain computers and the users on them To succeed, EAP-TLS (standalone or as a TEAP method) clients must meet these requirements:
Their certificate is valid and is not revoked, as validated by OCSP
The client's username matches an account in AD
# Requirements for assigning clients to roles
After authentication, the customer wants the CPPM to assign clients to ClearPass roles based on the following rules:
Clients with certificates issued by Onboard are assigned the "mobile-onboarded" role Clients that have passed TEAP Method 1 are assigned the "domain-computer" role Clients in the AD group "Medical" are assigned the "medical-staff" role Clients in the AD group "Reception" are assigned to the "reception-staff" role The customer requires CPPM to assign authenticated clients to AOS firewall roles as follows:
Assign medical staff on mobile-onboarded clients to the "medical-mobile" firewall role Assign other mobile-onboarded clients to the "mobile-other" firewall role Assign medical staff on domain computers to the "medical-domain" firewall role All reception staff on domain computers to the "reception-domain" firewall role All domain computers with no valid user logged in to the "computer-only" firewall role Deny other clients access
# Other requirements
Communications between ClearPass servers and on-prem AD domain controllers must be encrypted.
# Network topology
For the network infrastructure, this customer has Aruba APs and Aruba gateways, which are managed by Central. APs use tunneled WLANs, which tunnel traffic to the gateway cluster. The customer also has AOS-CX switches that are not managed by Central at this point.

# ClearPass cluster IP addressing and hostnames
A customer's ClearPass cluster has these IP addresses:
Publisher = 10.47.47.5
Subscriber 1 = 10.47.47.6
Subscriber 2 = 10.47.47.7
Virtual IP with Subscriber 1 and Subscriber 2 = 10.47.47.8
The customer's DNS server has these entries
cp.acnsxtest.com = 10.47.47.5
cps1.acnsxtest.com = 10.47.47.6
cps2.acnsxtest.com = 10.47.47.7
radius.acnsxtest.com = 10.47.47.8
onboard.acnsxtest.com = 10.47.47.8
You have imported the root certificate for the Windows CA to the ClearPass CA Trust list.
Which usages should you add to it based on the scenario requirements?

  • A. EAP and AD/LDAP Server
  • B. EAP and Radsec
  • C. LDAP and Aruba infrastructure
  • D. Radsec and Aruba infrastructure

Answer: A


NEW QUESTION # 37
Refer to the scenario.
# Introduction to the customer
You are helping a company add Aruba ClearPass to their network, which uses Aruba network infrastructure devices.
The company currently has a Windows domain and Windows CA. The Window CA issues certificates to domain computers, domain users, and servers such as domain controllers. An example of a certificate issued by the Windows CA is shown here.


The company is in the process of adding Microsoft Endpoint Manager (Intune) to manage its mobile clients.
The customer is maintaining the on-prem AD for now and uses Azure AD Connect to sync with Azure AD.
# Requirements for issuing certificates to mobile clients
The company wants to use ClearPass Onboard to deploy certificates automatically to mobile clients enrolled in Intune. During this process, Onboard should communicate with Azure AD to validate the clients. High availability should also be provided for this scenario; in other words, clients should be able to get certificates from Subscriber 2 if Subscriber 1 is down.
The Intune admins intend to create certificate profiles that include a UPN SAN with the UPN of the user who enrolled the device.
# Requirements for authenticating clients
The customer requires all types of clients to connect and authenticate on the same corporate SSID.
The company wants CPPM to use these authentication methods:
* EAP-TLS to authenticate users on mobile clients registered in Intune
* TEAR, with EAP-TLS as the inner method to authenticate Windows domain computers and the users on them To succeed, EAP-TLS (standalone or as a TEAP method) clients must meet these requirements:
Their certificate is valid and is not revoked, as validated by OCSP
The client's username matches an account in AD
# Requirements for assigning clients to roles
After authentication, the customer wants the CPPM to assign clients to ClearPass roles based on the following rules:
* Clients with certificates issued by Onboard are assigned the "mobile-onboarded" role
* Clients that have passed TEAP Method 1 are assigned the "domain-computer" role Clients in the AD group "Medical" are assigned the "medical-staff" role Clients in the AD group "Reception" are assigned to the "reception-staff" role The customer requires CPPM to assign authenticated clients to AOS firewall roles as follows:
* Assign medical staff on mobile-onboarded clients to the "medical-mobile" firewall role
* Assign other mobile-onboarded clients to the "mobile-other" firewall role
* Assign medical staff on domain computers to the "medical-domain" firewall role
* All reception staff on domain computers to the "reception-domain" firewall role
* All domain computers with no valid user logged in to the "computer-only" firewall role
* Deny other clients access
# Other requirements
Communications between ClearPass servers and on-prem AD domain controllers must be encrypted.
# Network topology
For the network infrastructure, this customer has Aruba APs and Aruba gateways, which are managed by Central. APs use tunneled WLANs, which tunnel traffic to the gateway cluster. The customer also has AOS-CX switches that are not managed by Central at this point.

# ClearPass cluster IP addressing and hostnames
A customer's ClearPass cluster has these IP addresses:
* Publisher = 10.47.47.5
* Subscriber 1 = 10.47.47.6
* Subscriber 2 = 10.47.47.7
* Virtual IP with Subscriber 1 and Subscriber 2 = 10.47.47.8
The customer's DNS server has these entries
* cp.acnsxtest.com = 10.47.47.5
* cps1.acnsxtest.com = 10.47.47.6
* cps2.acnsxtest.com = 10.47.47.7
* radius.acnsxtest.com = 10.47.47.8
* onboard.acnsxtest.com = 10.47.47.8
You have imported the root certificate for the Windows CA to the ClearPass CA Trust list.
Which usages should you add to it based on the scenario requirements?

  • A. EAP and AD/LDAP Server
  • B. EAP and Radsec
  • C. LDAP and Aruba infrastructure
  • D. Radsec and Aruba infrastructure

Answer: A


NEW QUESTION # 38
Refer to the scenario.
A customer is migrating from on-prem AD to Azure AD as its sole domain solution. The customer also manages both wired and wireless devices with Microsoft Endpoint Manager (Intune).
The customer wants to improve security for the network edge. You are helping the customer design a ClearPass deployment for this purpose. Aruba network devices will authenticate wireless and wired clients to an Aruba ClearPass Policy Manager (CPPM) cluster (which uses version 6.10).
The customer has several requirements for authentication. The clients should only pass EAP-TLS authentication if a query to Azure AD shows that they have accounts in Azure AD. To further refine the clients' privileges, ClearPass also should use information collected by Intune to make access control decisions.
The customer wants you to configure CPPM to collect information from Intune on demand during the authentication process.
What should you tell the Intune admins about the certificates issued to clients?

  • A. They must be issued by a ClearPass Onboard CA.
  • B. They must be issued by a well-known, trusted CA.
  • C. They must include the Intune ID in the subject name.
  • D. They must include the client MAC address in the subject name.

Answer: C

Explanation:
Explanation
To configure CPPM to collect information from Intune on demand during the authentication process, you need to use the Intune extension for ClearPass. This extension allows ClearPass to query Intune for device compliance and configuration information using the Intune API. To use this extension, you need to register an app in Azure AD and grant it the required permissions to access Intune1 The Intune extension uses the device ID as the key to query Intune for device information. The device ID is a unique identifier that is assigned by Intune to each enrolled device. The device ID can be obtained from the client certificate that is used for EAP-TLS authentication. Therefore, the certificates issued to clients must include the Intune ID in the subject name, so that ClearPass can extract it and use it to query Intune2 The certificates issued to clients do not need to be issued by a well-known, trusted CA, as long as ClearPass trusts the CA that issued them. The certificates do not need to include the client MAC address in the subject name, as this is not relevant for querying Intune. The certificates do not need to be issued by a ClearPass Onboard CA, as this is not a requirement for using the Intune extension.


NEW QUESTION # 39
......

Get ready to pass the HPE6-A84 Exam right now using our HP ACA - Network Security Exam Package: https://www.dumpsfree.com/HPE6-A84-valid-exam.html

A fully updated 2023 HPE6-A84 Exam Dumps exam guide from training expert DumpsFree: https://drive.google.com/open?id=1VzQda_1FTyoyBFyWpvOP7kN3SCNT7jhK