2023 Realistic NS0-162 Dumps Exam Tips Test Pdf Exam Material
Powerful NS0-162 PDF Dumps for NS0-162 Questions
The Network Appliance NS0-162 certification exam is designed to test the knowledge and skills of individuals who are seeking to become certified data administrators with a focus on the ONTAP storage operating system. The certification is offered by NetApp, a leading provider of hybrid cloud data services and data management solutions. The NS0-162 exam is one of the several certification exams offered by NetApp, and passing it is a requirement to become a certified data administrator with a focus on ONTAP.
The NS0-162 exam is a comprehensive test that covers various topics related to the management of NetApp ONTAP storage systems. The exam is divided into several sections, including storage system management, data protection, networking, and storage efficiency. The exam also covers advanced topics such as SAN and NAS protocols, high availability, disaster recovery, and data migration.
The NS0-162 exam consists of 60 multiple-choice questions that need to be completed within 90 minutes. The exam covers a range of topics related to NetApp data storage and management, including ONTAP software architecture, storage provisioning, data protection, backup and recovery, performance optimization, networking, and security. The exam tests the candidate's knowledge and skills in configuring, monitoring, and troubleshooting NetApp storage systems and provides a comprehensive assessment of their proficiency in managing and administering NetApp ONTAP solutions. Passing the NS0-162 exam validates a candidate's skills and knowledge in NetApp data storage solutions and demonstrates their expertise in managing and administering NetApp storage systems.
NEW QUESTION # 27
Click the Exhibit button.
Referring to the exhibit, which volume has a snap reserve value set to zero (0)?
- A. netapp_esx
- B. netapp_esx_m1
- C. netapp_n01
- D. netapp_Inx_m1
Answer: D
NEW QUESTION # 28
You are asked to deploy a two-node ONTAP Select system. The physical hardware is located in two different locations. You must ensure high availability and automated switchover.
Which two steps would you take to satisfy this requirement? (Choose two)
- A. Use Active IQ Unified Manager to provide a quorum for the two nodes.
- B. Ensure that the ONTAP Select Deploy VM resides at a third location other than the two datacenters.
- C. Ensure that the SyncMirror license is installed on the cluster.
- D. Use ONTAP Select Deploy to install the nodes on the physical hardware.
Answer: C,D
NEW QUESTION # 29
Exhibit
You have a 2-node FAS8300 switchless cluster. You ran the performance capacity report to see the last hour of performance
Referring to the exhibit, which two statements describe the performance? (Choose two.)
- A. The CPU has been underutilized.
- B. A storage failover event will cause performance issues.
- C. A storage failover event will have no performance degradation.
- D. The CPU has been over utilized.
Answer: B,D
NEW QUESTION # 30
You need to configure data-at-rest encryption for your NetApp ONTAP 9.8 cluster. Your company does not have Key Management Interoperability Protocol (KMIP) services available but must require a passphrase to be entered when a node Is rebooted.
In this scenario, which two actions should be performed to satisfy these requirements? (Choose two.)
- A. Enable onboard key management.
- B. Enable cluster-wide FlPS-compliant mode.
- C. Enable common criteria mode.
- D. Configure an external key management server.
Answer: A,C
Explanation:
Enabling onboard key management by default you are not required to enter a passphrase when the node is rebooted. To be asked the password , you need to enable the common criteria mode also.
NEW QUESTION # 31
Click the Exhibit button.
A customer is complaining about performance and wants to improve the latency for vol01.
Referring to the exhibit, what is affecting the performance?
- A. a QoS policy
- B. a disk
- C. the cluster
- D. the network
Answer: A
NEW QUESTION # 32
An application owner at your organization requests a solution for zero RTO In the event of a failure In your primary data center, where you are using NetApp ONTAP 9.8 software with ISCSI LUNs. The owner wants to avoid reconfiguring the application.
Which NetApp solution would you propose to fulfill these requirements?
- A. SyncMlrror
- B. SnapMirror Business Continuity (SM-BC)
- C. SVM Disaster Recovery (SVM DR)
- D. SnapMirror Synchronous (SMS)
Answer: D
NEW QUESTION # 33
Your company requires WORM archiving of data on their ONTAP cluster. The data must not be able to be deleted even by an administrator. Which ONTAP feature fulfills this requirement?
- A. SnapLock Enterprise
- B. SnapLock Compliance
- C. SnapVault software
- D. SnapMlrror software
Answer: C
NEW QUESTION # 34
What are the two capabilities of an SVM administrator? (Choose two.)
- A. to delegate an aggregate to the SVM
- B. to create LUNs
- C. to delete snapshot copies
- D. to create new users
Answer: B,C
NEW QUESTION # 35
You are the administrator of an ONTAP 9.8 cluster. Your company wants to know how many files are In the NAS volumes of the cluster and how old these files are.
Which two tools fulfill this requirement? (Choose two.)
- A. ONTAP CLI
- B. Active IQ Config Advisor
- C. ONTAP System Manager
- D. Active IQ Unified Manager
Answer: B,C
NEW QUESTION # 36
Your company requests that the monthly performance data of your ONTAP 9.8 cluster be exported to a CSV file for further processing. In this scenario, which three NetApp products satisfy this requirement? (Choose three.)
- A. Active IQ OneCollect
- B. Active IQ Config Advisor
- C. ONTAP System Manager
- D. Active IQ Unified Manager
- E. Cloud Insights
Answer: C,D,E
NEW QUESTION # 37
Exhibit.
A Linux host with the 10.0.1.24 IP address is unable to mount the VOL_A volume using NFSv3.
Referring to the exhibit, what is the problem?
- A. The logical Interface does not allow the NFSv3 protocol.
- B. The host IP address does not match the export policy rule.
- C. The volume is not mounted In the namespace.
- D. The volume is in read-only.
Answer: C
Explanation:
The volume is not mounted in the namespace. https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.cdot-famg-nfs%2FGUID-8E400D78-B405-4682-8F33-143783F2D580.html
Even if the volume was read only it could be mounted - also the client IP is in the desired range and LIF is configured for NFS.
NEW QUESTION # 38
You are asked to deploy a 2-node ONTAP Select cluster. The physical hardware Is located In two different locations and you want the aggregates mirrored synchronously between the two data centers. You must ensure high availability and automated switchover. In this scenario, which two steps would you take to fulfill this requirement? (Choose two.)
- A. Install the SnapMirror Sync license on the cluster.
- B. Ensure that the ONTAP Select Deploy VM resides at a third location other than the two data centers.
- C. Use ONTAP Mediator service to make sure that you have a quorum for the two nodes.
- D. Use ONTAP Select Deploy to Install the nodes on the physical hardware.
Answer: B,C
Explanation:
https://docs.netapp.com/us-en/ontap-select/reference_plan_ots_two_node.html When a cluster consists of two nodes, it is not possible to achieve the quorum required when a node fails or loses communication. To resolve these types of split-brain situations, every instance of the ONTAP Select Deploy utility includes a mediator service. If you have one or more active two-node clusters, the ONTAP Select Deploy virtual machine administering the clusters must be running at all times.
NEW QUESTION # 39
Your company has purchased two NetApp AFF A400 HA pairs. During deployment, how many root aggregates are created?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION # 40
Click the Exhibit button.
The volumes shown in the exhibit, vol1 and vol2, are in the same AFF aggregate. You write the same large 100 GB file to both vol1 and vol2.
Based on the volume efficiency settings, which action occurs?
- A. The files are deduplicated at the volume level.
- B. The files are queued for a background deduplication schedule.
- C. The files are deduplicated at the aggregate level.
- D. The files are deduplicated at the SVM level by SVM1.
Answer: A
NEW QUESTION # 41
You have an ESXI cluster with VMware VMFS LUNs on an AFF A400 system. After troubleshooting performance Issues, you determine that timeout best practices are not set on the hosts.
In this scenario, which NetApp tool would apply the best practice settings?
- A. Virtual Storage Console (VSC)
- B. SnapManager
- C. SAN Host Utilities
- D. SnapCenter Plug-in for VMware vSphere
Answer: A
Explanation:
Reference:
Virtual Storage Console for VMware vSphere checks and sets the ESXi host multipathing settings and HBA timeout settings that work best with NetApp storage systems.
NEW QUESTION # 42
The source NAS volume of a SnapMirror relationship is unavailable due to networking issues at your organization's primary data center. You want to make the destination NAS volume writable so that clients are able to access their data.
Which two steps do you need to take to solve the issue? (Choose two.)
- A. Use the volume mount command to mount the NAS volume In the NFS namespace.
- B. Delete the SnapMirror relationship from the destination cluster.
- C. Break the SnapMirror relationship using the snapmirror break command from the source cluster.
- D. Break the SnapMirror relationship using the snapairrcr break command from the destination cluster.
Answer: A,D
NEW QUESTION # 43
Exhibit.
You have an SVM-DR relationship as shown in the exhibit. You are given a new requirement to use SnapMirror Synchronous (SMS) for the data volumes In NFS-SVM-01.
In this scenario, which solution Is supported to enable SMS in ONTAP 9.8 software?
- A. Modify the existing SVM-DR policy to use sync mode.
- B. Set up NetApp Cloud Sync with a cloud broker in AWS to replicate to a new destination.
- C. Set up new SM-S relationships from the FAS2720 to a new destination.
- D. Set up new SM-S relationships from the AFF A220 to a new destination.
Answer: B
NEW QUESTION # 44
Exhibit.
After an ONTAP upgrade, you notice that several cluster LIFs are not on their home ports as shown in the exhibit.
Which LIF option would change this outcome?
- A. the failover-policy option
- B. the auto-revert option
- C. the data-protocol option
- D. the subnet-name option
Answer: B
Explanation:
https://docs.netapp.com/us-en/ontap/networking/revert_a_lif_to_its_home_port.html
NEW QUESTION # 45
An application owner at your organization requests a solution for zero RTO In the event of a failure In your primary data center, where you are using NetApp ONTAP 9.8 software with ISCSI LUNs. The owner wants to avoid reconfiguring the application.
Which NetApp solution would you propose to fulfill these requirements?
- A. SyncMlrror
- B. SVM Disaster Recovery (SVM DR)
- C. SnapMirror Synchronous (SMS)
- D. SnapMirror Business Continuity (SM-BC)
Answer: D
NEW QUESTION # 46
Exhibit.
You have a 2-node NetApp FAS2750 ONTAP cluster. You create a new 20-GB LUN In a new 100-GB volume and write 10 GB of data to the LUN. No storage efficiencies are enabled for the volume or aggregate.
Referring to the exhibit, which two statements are true? (Choose two.)
- A. ONTAP reports the volume as 20% full.
- B. ONTAP reports that the volume Is using 10 GB of Its containing aggregate.
- C. ONTAP reports that the volume Is using 100 GB of its containing aggregate.
- D. ONTAP reports the volume as 10% full.
Answer: A,B
NEW QUESTION # 47
......
Guaranteed Accomplishment with Newest May-2023 FREE: https://www.dumpsfree.com/NS0-162-valid-exam.html
Authentic NS0-162 Dumps - Free PDF Questions to Pass: https://drive.google.com/open?id=1jc46Chd5Pqc6L1lLBezivvd8IycU_5xM